Engineers use fluid simulation and vibration testing to evaluate how vehicles, components, and fluid handling systems perform under controlled conditions. In aerospace applications, substitute liquids can reproduce important physical properties of rocket propellants, such as density and viscosity, without introducing the same handling hazards. Similar testing principles also apply to aircraft, automotive systems, industrial equipment, and other machinery.
BestSolv® engineered fluids offer potential alternatives for these applications. For example, BestSolv® 7100 is an exact-molecule replacement for 3M™ Novec™ 7100, a fluid NASA selected as an oxidizer simulant during testing of its Orion spacecraft.
Whether the application involves propellant simulation, tank filling and draining, or aerospace vibration testing, selecting the appropriate engineered fluid helps engineers reproduce the physical conditions required for reliable testing.
What Is Fluid Simulation?
Fluid simulation involves using a substitute liquid to reproduce specific characteristics of another fluid under controlled testing conditions. These liquids, sometimes called simulant fluids or referee fluids, allow engineers to test equipment without necessarily using the actual fluid that will be present during operation.
In aerospace testing, engineers may fill propulsion tanks with a simulant fluid to reproduce the mass and dynamic behavior associated with flight propellants.
This approach allows researchers and manufacturers to evaluate equipment performance, structural response, fluid handling, and system behavior during testing.
Fluid simulation may be used for:
- Spacecraft and launch vehicle propulsion tank testing
- Aircraft and helicopter fluid system testing
- Aerospace vibration and structural testing
- Automotive and industrial fluid handling systems
- Fluid transfer and pressurization system testing
- Laboratory evaluation of fluid handling equipment
The specific fluid requirements depend on what the test must reproduce and how the fluid interacts with the equipment.
Why Are Engineered Fluids Used for Aerospace Testing?
Aerospace engineers sometimes need to fill spacecraft tanks with liquids that behave similarly to actual rocket propellants. However, using real propellants during testing can introduce significant safety hazards, including toxicity, flammability, and chemical reactivity.
Engineered fluids offer an alternative by reproducing important physical characteristics of those liquids without necessarily introducing the same hazards.
For example, NASA selected 3M™ Novec™ HFE-7100 as an oxidizer simulant for its Orion spacecraft testing program because of four important characteristics:
- Density: Its density was close to that of the actual oxidizer, helping reproduce the required liquid mass inside the tank.
- Viscosity: Its flow characteristics were suitable for the testing requirements.
- Nonflammability: It helped reduce fire hazards during testing.
- Low Toxicity: Its toxicological characteristics reduced certain handling hazards compared with the actual propellant.
Because BestSolv® 7100 is an exact-molecule alternative to 3M™ Novec™ 7100, it offers a relevant option for engineers evaluating fluids for similar testing applications.
The result is the ability to reproduce important testing conditions while reducing certain risks associated with handling actual rocket propellants.
Fluid Simulation in Aerospace Vibration Testing
Aircraft, helicopters, launch vehicles, and spacecraft experience vibration and mechanical forces during operation. Engineers conduct vibration tests to evaluate how components and assemblies respond to these conditions. When fluid-filled systems are involved, substitute liquids may help reproduce the mass and movement of operational fluids without using the actual liquids during testing.
For spacecraft containing propulsion tanks, the mass and distribution of liquid inside the tanks can influence their dynamic response.
Instead of using actual propellants, engineers may introduce a substitute fluid with suitable physical properties.
In these applications, engineers may use substitute fluids during filling, draining, pressurization, and other testing operations. The selected fluid must reproduce the physical characteristics relevant to the test, which may include density, viscosity, and fluid movement.
This application demonstrates the established use of engineered hydrofluoroether (HFE) fluids in aerospace testing and provides a relevant technical reference for organizations evaluating replacements for 3M™ Novec™ fluids.
Why Use Engineered Fluids Instead of IPA or Water?
Isopropyl alcohol (IPA) and water have traditionally been used as substitute liquids in certain aerospace testing applications. However, each introduces considerations that may affect test safety, preparation, and post-test processing.
Isopropyl Alcohol (IPA)
IPA is highly flammable, creating additional safety concerns when used in testing equipment, particularly where leaks, vapors, or ignition sources may be present.
Engineered fluids with appropriate flammability characteristics may offer an alternative for applications where reducing flammable-liquid hazards is a priority.
Water
Water is inexpensive and nonflammable, but it may require extensive drying after testing. Residual moisture can also create concerns for sensitive components or materials that are susceptible to corrosion.
Engineered Fluids
Certain BestSolv® engineered fluids offer combinations of properties such as low viscosity, controlled volatility, low surface tension, and favorable electrical characteristics.
Depending on the formulation, these characteristics may help address specific testing requirements, including fluid handling, drying, material compatibility, and safety.
However, a substitute fluid must be selected according to the physical properties and operating conditions required by the test. Not every engineered fluid is appropriate for every application.
BestSolv® Engineered Fluids for Fluid Simulation and Vibration Testing
Best Technology offers several engineered fluids that can be evaluated for specialized fluid simulation applications.
BestSolv® 7100: Exact-Molecule Alternative to 3M™ Novec™ 7100
BestSolv® 7100 is an exact-molecule alternative to 3M™ Novec™ 7100 Engineered Fluid.
Because 3M™ Novec™ HFE-7100 has documented use as an aerospace propellant simulant, BestSolv® 7100 provides a relevant starting point for organizations seeking to replace legacy 7100 fluid in comparable testing applications.
Key physical properties include:
- Boiling point: approximately 61°C
- Vapor pressure: approximately 210 mmHg at 20°C
- Liquid density: approximately 1.50 g/cm³
Why These Properties Matter for Fluid Simulation
The density of BestSolv® 7100, approximately 1.50 g/cm³, is particularly relevant when simulating a liquid with a similar density. In aerospace vibration testing, reproducing the appropriate liquid mass can help engineers evaluate how a filled propulsion tank responds to mechanical loads.
Its low viscosity is also important for fluid handling operations, while its nonflammable characteristics can help reduce fire hazards compared with flammable alternatives such as IPA.
These characteristics make BestSolv® 7100 a relevant candidate for aerospace fluid simulation applications where the original 3M™ Novec™ 7100 was specified.
Its established molecular equivalence makes it an important candidate where the original testing procedure specifies HFE-7100.
Application-specific qualification and material compatibility evaluation remain necessary.
BestSolv® Sierra: Similar-Molecule Alternative to Novec™ 7100
BestSolv® Sierra is a high-purity hydrofluoroether designed as a similar-molecule alternative to 3M™ Novec™ 7100.
With physical properties comparable to HFE-7100, Sierra has been used as an alternative to 7100 in customer applications, according to Best Technology’s chemical team. It is also a relevant option for fluid simulation and vibration testing applications where an exact molecular match is not required and its physical properties meet the testing requirements.
Key physical properties include:
- Boiling point: approximately 56°C
- Vapor pressure: approximately 232 mmHg at 20°C
- Liquid density: approximately 1.47 g/cm³
Sierra is nonflammable and offers a potential alternative for applications where fluid volatility, density, and material compatibility meet the required test specifications.
Its suitability for a particular vibration test must be evaluated against the original fluid and test requirements.
BestSolv® Bravo: An Option for Higher-Volatility Requirements
BestSolv® Bravo is an engineered fluid formulation with higher vapor pressure than BestSolv® Sierra and 7100.
Bravo may be evaluated for specialized testing applications requiring higher volatility, depending on fluid properties and material compatibility. Its primary established applications include precision flushing and vapor degreasing to remove oils, greases, and particulate contaminants from equipment, making it a potential option for cleaning test hardware after vibration testing.
Key physical properties include:
- Boiling point: approximately 45.5°C (114°F)
- Vapor pressure: approximately 367 mmHg at 20°C
- Liquid density: approximately 1.27 g/cm³
Because Bravo has a different formulation from neat HFE-7100, particular attention must be given to chamber construction, gasket materials, chemical compatibility, and the fluid’s flammability characteristics.
Bravo should be evaluated against the requirements of the specific testing application rather than assumed to be interchangeable with HFE-7100.
How to Select a Fluid for Aerospace Testing
Selecting the correct fluid requires understanding both the purpose of the test and the properties of the original liquid being simulated.
Important considerations include:
Liquid Density: Determines the mass of fluid occupying a given volume and may influence the dynamic response of tanks and structures.
Viscosity: Influences fluid movement, resistance to flow, and behavior during filling, draining, or dynamic testing.
Vapor Pressure and Evaporation Rate: Affect fluid volatility, vapor management, drying requirements, and potentially test conditions.
Material Compatibility: The selected fluid must be compatible with chamber materials, seals, gaskets, hoses, and other wetted components.
Flammability and Safety: Fluid handling characteristics must be assessed against the safety requirements of the testing environment.
Cleanliness and Residue: Testing fluids should meet the contamination-control requirements of the equipment, particularly when used in sensitive aerospace assemblies.
The relative importance of these properties varies. For example, a fluid used to simulate the mass of propellant inside a tank may require different characteristics than one selected primarily for transfer-system evaluation or controlled evaporation.
To compare available formulations and their specifications, explore the complete BestSolv® engineered fluids product lineup.
Discuss Your Fluid Simulation Requirements With Best Technology
Whether you are replacing 3M™ Novec™ 7100 in an existing aerospace testing process or evaluating engineered fluids for a new test program, selecting the correct fluid is essential to achieving reliable results.
Best Technology‘s chemical application specialists can help you compare BestSolv® engineered fluids according to your required physical properties, equipment materials, and testing conditions.
Contact Best Technology to discuss BestSolv® engineered fluid options for your fluid simulation or vibration testing application.